国产成人免费在线播放_亚洲AV免费看日韩_国产日产欧产精品精品推荐在线_久久精品国产亚洲日本波多野结衣_最近最好中文字幕电影_国产精品福利在线观看一区_月夜直播视频下载_亚洲欧美综合中文_成 人免费va视频_成年美女18禁黄网站免费_国产一级 片内射视频播放免_久久福利青草免费精品

Focused on the control systems solutions for fluid metering systems, and integrating various types of R & D, manufacturing, precision micro-liquid filling, measurement, atomization, liquid injection etc.

Telephone:
0769-83328418

News center

Contact us

Dongguan Ji kerr automation Technology Co., LTD

Telephone:0769-83328418
Fax:0769-83328428
Email:dgjikeer@126.com
Address:80 Luxi Road, Xixi Village, Liaobu Town, Dongguan City, Guangdong Province

Dongguan Ji kerr automation Technology Co., LTD

common problem

Home > News center > common problem

News center > common problem

Ji kerr injection pump daily maintenance failure and treatment

Date:2018-11-13  browse:593

Ji kerr injection pump daily maintenance failure and treatment

In the long-term use of the equipment, some minor faults are inevitable, as long as the correct response method is mastered,

 the site can be easily solved, which will help the equipment to maintain good working conditions, improve work efficiency,

 and greatly shorten the equipment downtime. The following are some troubleshooting measures that this machine may encounter:

Fault phenomenon

Fault analysis

Treatment method

 

 

Power      failure   

Whether the power supply voltage is input

Check line and grid voltage               

Whether the 24V power supply has input

Repair and replacement

Check the open fuse box

Replacement insurance

Switching circuit

Check and replace

 

 

 

Motor failure

Check the step power supply

Inspection and maintenance line

Abnormal motor overheating

The drive current is too large or the motor speed per second is set too large.

Motor driver anomaly

Check whether the driver indicator is on and replace it

Check whether the motor is connected correctly

Check the motor wiring method

The electrolyte disconnects and the pump core is stuck

Clean pump core

Bubble formation

Check pump sleeve end cover

Lock the end cover                   

The inlet and outlet pipe is loose

Lock the end cap inlet and outlet pipe

The electrolyte was not vacuumed and left standing

It is recommended to vacuum and stand the electrolyte

I can't get any fluids

Whether the inlet and outlet conduits are connected in reverse

Drop the catheter position

Inlet and outlet conduits are not aligned

Lock the inlet and outlet pipe connector in position

Top cover is not locked in position

Lock the top cover in position

Liquid ejection

Liquid ejection

Reduce the electric speed, reduce the flow rate or increase the outlet tube needle

Abnormal alarm

Sensors are not communicating properly

Check the 24V supply circuit

Sensor light is not on

Sensor replacement

Motor not in place

Just clear the alarm

Motor not in place

Check whether the light is on when the photoelectric switch is powered on. If it is not on, replace it

Motor not in place

Motor speed exceeds step subdivision, restart the power supply

Loose aviation joint

Locking joint

 

 


Dongguan Ji kerr automation Technology Co., LTD

Scan to enter the mobile website

©2018-2020 Dongguan Ji kerr automation Technology Co., LTD copyright  粵ICP備15074133號  technical support:ytclouds